Iranian Journal of Orthodontics

Iranian Journal of Orthodontics

Microleakage of Orthodontic Fixed Retainers Bonded with Zinc Oxide- and Silver Nanoparticle-Modified Adhesives: An in Vitro Study

Document Type : Original Article

Authors
1 Department of Orthodontics and Dentofacial Orthopedics, Faculty of Dental Sciences, MS Ramaiah University of Applied Sciences, Bengaluru, India
2 Department of Orthodontics and Dentofacial Orthopedics, Vokkaligara Sangha Dental College and Hospital, Bengaluru, India
3 Department of Orthodontics and Dentofacial Orthopedics, KGF College of Dental Sciences and Hospital, Kolar Gold Fields, India
10.22034/ijo.2026.2089765.1494
Abstract
Aim: Fixed orthodontic retainers are widely used to maintain post-treatment dental alignment; however, microleakage at the adhesive-enamel interface can compromise their long-term performance. Incorporation of nanoparticles into orthodontic adhesives has recently gained attention as an approach to modify adhesive properties and influence microleakage behavior. This study aimed to compare microleakage in fixed orthodontic retainers bonded with conventional adhesives versus adhesives modified with 1% zinc oxide (ZnO) and 1% silver (Ag) nanoparticles.
Methods: Sixty extracted human mandibular central incisors were randomly allocated into six subgroups (n = 10 per subgroup): ZnO-modified Transbond XT (group 1a), ZnO-modified Enlight (group 1b), Ag-modified Transbond XT (group 2a), Ag-modified Enlight (group 2b), unmodified Transbond XT (group 3a), and unmodified Enlight (group 3b). A 0.0175-inch multistranded stainless steel wire was bonded to each lingual surface, and specimens underwent 1500 thermocycles (5°C-55°C). Microleakage was assessed using a stereomicroscope at 10x magnification.
Results: ZnO-modified groups recorded the lowest mean microleakage (0.0385 ± 0.0556 and 0.0314 ± 0.1223). The data were non-normal with unequal variances, so the Kruskal–Wallis test was the primary analysis and showed a significant difference across groups (H = 12.96, p = 0.023). Dunn’s post hoc test (Bonferroni) showed both ZnO groups had significantly lower microleakage than the Ag-modified and unmodified groups (adjusted p = 0.01–0.04).
Conclusion: The ZnO-modified groups had significantly lower microleakage at the adhesive-enamel interface than the Ag-modified and unmodified adhesives. Studies with larger samples are required to confirm whether ZnO modification improves the marginal seal of bonded orthodontic retainers.
Keywords
Subjects

1. Jedliński M, Mazur M, Salerno C, Grocholewicz K, Janiszewska-Olszowska J. Impact of bonding protocols and physical-mechanical properties of composite on durability and failure rate of fixed orthodontic retainers: a systematic review of laboratory studies. BMC Oral Health. 2025 ;25(1):1255. doi: 10.1186/s12903-025-06635-6.
2. Singh S. Microleakage Studies - A Viewpoint. J Conserv Dent. 2023;26(1):1-2. doi: 10.4103/jcd.jcd_1_23.
3. Nalbantgil D, Oztoprak MO, Cakan DG, Bozkurt K, Arun T. Prevention of demineralization around orthodontic brackets using two different fluoride varnishes. Eur J Dent. 2013;7(1):41-7.
4. Ferreira LA, Sapata DM, Provenzano MGA, Hayacibara RM, Ramos AL. Periodontal parameters of two types of 3 x 3 orthodontic retainer: a longitudinal study. Dental Press J Orthod. 2019 ;24(3):64-70. doi: 10.1590/2177-6709.24.3.064-070.oar.
5. Prasad M, Mohamed S, Nayak K, Shetty SK, Talapaneni AK. Effect of moisture, saliva, and blood contamination on the shear bond strength of brackets bonded with a conventional bonding system and self-etched bonding system. J Nat Sci Biol Med. 2014;5(1):123-9. doi: 10.4103/0976-9668.127305.
6. Alkis H, Turkkahraman H, Adanir N. Microleakage under orthodontic brackets bonded with different adhesive systems. Eur J Dent. 2015;9(1):117-121. doi: 10.4103/1305-7456.149656.
7. Naguib G, Maghrabi AA, Mira AI, Mously HA, Hajjaj M, Hamed MT. Influence of inorganic nanoparticles on dental materials' mechanical properties. A narrative review. BMC Oral Health. 2023 ;23(1):897. doi: 10.1186/s12903-023-03652-1.
8. Zhang K, Wang S, Zhou X, Xu HH, Weir MD, Ge Y, etal. Effect of antibacterial dental adhesive on multispecies biofilms formation. J Dent Res. 2015;94(4):622-9. doi: 10.1177/0022034515571416.
9. Rai M, Yadav A, Gade A. Silver nanoparticles as a new generation of antimicrobials. Biotechnol Adv. 2009;27(1):76-83. doi: 10.1016/j.biotechadv.2008.09.002.
10. Tavassoli Hojati S, Alaghemand H, Hamze F, Ahmadian Babaki F, Rajab-Nia R, Rezvani MB, etal. Antibacterial, physical and mechanical properties of flowable resin composites containing zinc oxide nanoparticles. Dent Mater. 2013;29(5):495-505. doi: 10.1016/j.dental.2013.03.011.
11. Ahn SJ, Lee SJ, Kook JK, Lim BS. Experimental antimicrobial orthodontic adhesives using nanofillers and silver nanoparticles. Dent Mater. 2009;25(2):206-13. doi: 10.1016/j.dental.2008.06.002.
12. Jia A, Wang P, Tong F, Chen Z, Deng Y, Yao H, Wang L, Liu Y, Ge H. Developing a novel enamel adhesive with amorphous calcium phosphate and silver nanoparticles to prevent demineralization during orthodontic treatment. J Funct Biomater. 2023 ;14(2):77. doi: 10.3390/jfb14020077.
13. Jazi L, Sodagar A, Kazemi SS, Mirhashemi A. Evaluation and comparison of the effect of incorporating zinc oxide and titanium dioxide nanoparticles on the bond strength and microleakage of two orthodontic fixed retainer adhesives. J World Fed Orthod. 2023;12(1):22-28. doi: 10.1016/j.ejwf.2022.09.002.
14. Teymoornezhad K, Alaghehmand H, Daryakenari G, Khafri S, Tabari M. Evaluating the microshear bond strength and microleakage of flowable composites containing zinc oxide nano-particles. Electron Physician. 2016 ;8(11):3289-3295. doi: 10.19082/3289.
15. Masarykova N, Tkadlec E, Chlup Z, Vrbsky J, Brysova A, Cernochova P, etal. Comparison of microleakage under orthodontic brackets bonded with five different adhesive systems: in vitro study. BMC Oral Health. 2023 ;23(1):637. doi: 10.1186/s12903-023-03368-2.
16. Toodehzaeim MH, Haerian A, Hazeri Baqdad Abad M, Hatami P. Comparison of microleakage of orthodontic brackets bonded with copper oxide and zinc oxide nanoparticles-containing composites. J Regen Recons Restor. 2025; 10: e12. Doi: 10.22037/rrr.v10.47417.
17. Ulker M, Uysal T, Ramoglu SI, Ertas H. Microleakage under orthodontic brackets using high-intensity curing lights. Angle Orthod. 2009 Jan;79(1):144-9. doi: 10.2319/111607-534.1.
18. arszczewska-Rybarek I, Chladek G. Studies on the Curing Efficiency and Mechanical Properties of Bis-GMA and TEGDMA Nanocomposites Containing Silver Nanoparticles. Int J Mol Sci. 2018 Dec 7;19(12):3937. doi: 10.3390/ijms19123937.
19. Degrazia FW, Leitune VC, Garcia IM, Arthur RA, Samuel SM, Collares FM. Effect of silver nanoparticles on the physicochemical and antimicrobial properties of an orthodontic adhesive. J Appl Oral Sci. 2016 Jul-Aug;24(4):404-10. doi: 10.1590/1678-775720160154.
20. Štruncová M, Toma SH, Araki K, Bresciani E, Rodrigues FP, Medeiros IS, Dutra-Correa M. Silver nanoparticles added to a commercial adhesive primer: Colour change and resin colour stability with ageing. International Journal of Adhesion and Adhesives. 2020 Oct 1;102:102694.doi:10.1016/j.ijadhadh.2020.102694.
21. Alayed A, Silikas N, Watts DC. The effect of photoinitiator systems on resin-based composite containing ZnO-nanoparticles. Dent Mater. 2025 Feb;41(2):220-228. doi: 10.1016/j.dental.2024.12.002.
22. Yagci A, Uysal T, Ertas H, Amasyali M. Microleakage between composite/wire and composite/enamel interfaces of flexible spiral wire retainers: direct versus indirect application methods. Orthod Craniofac Res. 2010;13(2):118-24. doi: 10.1111/j.1601-6343.2010.01486.x. 
23. Saeed F, Ilyas M, Shaheen A. An In Vitro Study Comparing the antibacterial and mechanical properties of zinc oxide-based nanofillers in orthodontic adhesives for white spot lesion prevention in fixed orthodontic therapy. Cureus. 2024 ;16(8):e66967. doi: 10.7759/cureus.66967.

Articles in Press, Accepted Manuscript
Available Online from 27 November 2026