Aim
To evaluate stress distribution and displacement patterns during infrazygomatic crest (IZC)–supported full‑arch distalization with intrusion and to compare the biomechanical performance of single versus dual anterior temporary anchorage device (TAD) configurations using finite element analysis.
Methods
 A CBCT‑based three‑dimensional finite element model of the maxillary dentoalveolar complex was constructed, including teeth, periodontal ligament (PDL), cortical and cancellous bone, archwire, IZC screws, and TADs. Two anchorage configurations were simulated: a single anterior TAD placed between the maxillary central incisors and dual anterior TADs placed bilaterally between the central and lateral incisors, both combined with IZC screws. Distalization forces ranging from 50 to 700 g were applied with a constant intrusive force of 50 g. Von Mises stress distribution and displacement patterns were evaluated in the cortical bone, PDL, dental roots, and anchorage components.
Results
Fourteen loading conditions (50–700 g distalization combined with 50 g intrusion) were analyzed. At low force levels (50–250 g), stresses remained within physiologic limits, with root stress ranging from 1.40 to 1.80 MPa and PDL stress from 0.015 to 0.020 MPa. With moderate forces (300–475 g), stresses increased, and root stress reached 2.88–3.03 MPa while PDL stress ranged from 0.026 to 0.030 MPa. At higher forces (500–700 g), stress levels further increased, with root stress ranging from 4.18 to 4.38 MPa and PDL stress from 0.041 to 0.044 MPa, indicating a potential overload region. Overall, stress and displacement values increased proportionally with increasing distalization force. The dual TAD configuration consistently demonstrated more favorable biomechanical behavior than the single‑TAD model, showing lower stress concentrations in cortical bone and the periodontal ligament, more uniform stress distribution, and reduced displacement of the maxillary teeth.
Conclusion
Dual anterior TAD reinforcement during IZC-supported full-arch distalization with intrusion demonstrated a more uniform stress distribution and lower displacement values compared with the single TAD configuration, suggesting differences in biomechanical behavior between the two anchorage systems. Careful regulation of distalization force magnitude may help minimize localized stress within the dentoalveolar structures during skeletal anchorage–supported maxillary distalization.
Keywords
Subjects

1.  Brezniak N, Wasserstein A. Root resorption after orthodontic treatment: Part 1. Literature review. Am J Orthod Dentofacial Orthop. 1993;103(1):62-6. doi: 10.1016/0889-5406(93)70106-X.
2. Brezniak N, Wasserstein A. Orthodontically induced inflammatory root resorption. Part II: The clinical aspects. Angle Orthod. 2002;72(2):180-4. doi: 10.1043/0003-3219(2002)072<0180:OIIRRP>2.0.CO;2.
3. Samandara A, Papageorgiou SN, Ioannidou-Marathiotou I, Kavvadia-Tsatala S, Papadopoulos MA. Evaluation of orthodontically induced external root resorption following orthodontic treatment using cone beam computed tomography (CBCT): a systematic review and meta-analysis. Eur J Orthod. 2019;41(1):67-79. doi: 10.1093/ejo/cjy027.
4. Yassir YA, McIntyre GT, Bearn DR. Orthodontic treatment and root resorption: an overview of systematic reviews. Eur J Orthod. 2021;43(4):442-456. doi: 10.1093/ejo/cjaa058.
5. Weltman B, Vig KW, Fields HW, Shanker S, Kaizar EE. Root resorption associated with orthodontic tooth movement: a systematic review. Am J Orthod Dentofacial Orthop. 2010;137(4):462-76; discussion 12A. doi: 10.1016/j.ajodo.2009.06.021.
6. Bellini-Pereira SA, Almeida J, Aliaga-Del Castillo A, Dos Santos CCO, Henriques JFC, Janson G. Evaluation of root resorption following orthodontic intrusion: a systematic review and meta-analysis. Eur J Orthod. 2021;43(4):432-441. doi: 10.1093/ejo/cjaa054.
7. Huang TTY, Elekdag-Turk S, Dalci O, Almuzian M, Karadeniz EI, Gonzales C, Petocz P, Turk T, Darendeliler MA. The extent of root resorption and tooth movement following the application of ascending and descending magnetic forces: a prospective split-mouth, microcomputed-tomography study. Eur J Orthod. 2017;39(5):547-553. doi: 10.1093/ejo/cjw073.
8. Antonarakis GS, Zekeridou A, Kiliaridis S, Giannopoulou C. Periodontal considerations during orthodontic intrusion and extrusion in healthy and reduced periodontium. Periodontol 2000. 2024. doi: 10.1111/prd.12578.
9. Roscoe MG, Meira JB, Cattaneo PM. Association of orthodontic force system and root resorption: A systematic review. Am J Orthod Dentofacial Orthop. 2015;147(5):610-26. doi: 10.1016/j.ajodo.2014.12.026.
10. Schwertner A, de Almeida-Pedrin RR, Poleti TMFF, Oltramari P, de Castro Conti ACF, Cotrim-Ferreira FA, de Almeida G, Flores-Mir C, de Almeida MR. Biomechanical analysis of total arch maxillary distalization using infrazygomatic crest miniscrews: a finite element analysis study. Prog Orthod. 2024;25(1):10. doi: 10.1186/s40510-024-00509-3.
11. de Almeida MR. Clinical considerations for total arch distalization using extra-alveolar mini screws – An overview. Semin Orthod .2025;32(3): 557-567 .doi: 10.1053/j.sodo.2025.07.005 
12. Ghosh A. Infra-zygomatic crest and buccal shelf-orthodontic bone screws: a leap ahead of micro-implants-clinical perspectives. J Indian Orthod Soc 2018;52(4 Suppl 2):127-141.doi: 10.4103/jios.jios_229_18.
13. Alkadhimi A. Distalization with extra-alveolar temporary anchorage devices in the infrazygomatic crest region. Orthod Update 2025;18(3):115-124.doi: 10.12968/ortu.2025.18.3.115.
14. Rosa WGN, de Almeida-Pedrin RR, Oltramari PVP, de Castro Conti ACF, Poleti TMFF, Shroff B, de Almeida MR. Total arch maxillary distalization using infrazygomatic crest miniscrews in the treatment of Class II malocclusion: a prospective study. Angle Orthod. 2023 ;93(1):41-48. doi: 10.2319/050122-326.1.
15. Shaikh A, Jamdar AF, Galgali SA, Patil S, Patel I, Hemagiriyappa MS. Efficacy of Infrazygomatic Crest Implants for Full-arch Distalization of Maxilla and Reduction of Gummy Smile in Class II Malocclusion. J Contemp Dent Pract. 2021;22(10):1135-1143.
16. Wu X, Liu H, Luo C, Li Y, Ding Y. Three-Dimensional Evaluation on the Effect of Maxillary Dentition Distalization With Miniscrews Implanted in the Infrazygomatic Crest. Implant Dent. 2018;27(1):22-27. doi: 10.1097/ID.0000000000000706.
17. Papadopoulos MA, Tarawneh F. The use of miniscrew implants for temporary skeletal anchorage in orthodontics: a comprehensive review. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2007;103(5):e6-15. doi: 10.1016/j.tripleo.2006.11.022.
18. Liou EJ, Pai BC, Lin JC. Do miniscrews remain stationary under orthodontic forces? Am J Orthod Dentofacial Orthop. 2004;126(1):42-7. doi: 10.1016/j.ajodo.2003.06.018.
19. Motoyoshi M, Hirabayashi M, Uemura M, Shimizu N. Recommended placement torque when tightening an orthodontic mini-implant. Clin Oral Implants Res. 2006;17(1):109-14. doi: 10.1111/j.1600-0501.2005.01211.x.
20. Moss ML, Skalak R, Patel H, Sen K, Moss-Salentijn L, Shinozuka M, Vilmann H. Finite element method modeling of craniofacial growth. Am J Orthod. 1985;87(6):453-72. doi: 10.1016/0002-9416(85)90084-3.
21. Khosravi S, Jahanshad H, Moafi M, Shahmohamadi M, Kachoei M. Miniscrew placement on mandibular buccal shelf and infra-zygomatic crest area: A finite element analysis. J Adv Periodontol Implant Dent. 2025 ;17(4):205-215. doi: 10.34172/japid.025.3687.
22. Oğuz F, Özden S. Finite element analysis of maxillary arch distalization using skeletal anchorage at three different application regions. Sci Rep. 2025 ;15(1):24073. doi: 10.1038/s41598-025-10035-9.
23. Fares M, Marzouk W, Ismail HA, Abuouf Y, Kassem HE. Effect of multiple hook heights and positions during en masse maxillary distalization using infrazygomatic crest miniscrew- single and double points of force application: a finite element analysis study. BMC Oral Health. 2025 ;25(1):771. doi: 10.1186/s12903-025-06138-4.
24. Tanne K, Sakuda M, Burstone CJ. Three-dimensional finite element analysis for stress in the periodontal tissue by orthodontic forces. Am J Orthod Dentofacial Orthop. 1987;92(6):499-505. doi: 10.1016/0889-5406(87)90232-0.
25. Melsen B. Tissue reaction to orthodontic tooth movement--a new paradigm. Eur J Orthod. 2001;23(6):671-81. doi: 10.1093/ejo/23.6.671.
26. Cattaneo PM, Dalstra M, Melsen B. The finite element method: a tool to study orthodontic tooth movement. J Dent Res. 2005;84(5):428-33. doi: 10.1177/154405910508400506.
27. Kravitz ND, Kusnoto B. Risks and complications of orthodontic miniscrews. Am J Orthod Dentofacial Orthop. 2007;131(4 Suppl):S43-51. doi: 10.1016/j.ajodo.2006.04.027.
28. Wilmes B, Drescher D. Impact of insertion depth and predrilling diameter on primary stability of orthodontic mini-implants. Angle Orthod. 2009;79(4):609-14. doi: 10.2319/071708-373.1.
29. Lee JS, Kim DH, Park YC, Kyung SH, Kim TK. The efficient use of midpalatal miniscrew implants. Angle Orthod. 2004;74(5):711-4. doi: 10.1043/0003-3219(2004)074<0711:TEUOMM>2.0.CO;2.
30. Chan E, Darendeliler MA. Physical properties of root cementum: Part 5. Volumetric analysis of root resorption craters after application of light and heavy orthodontic forces. Am J Orthod Dentofacial Orthop. 2005;127(2):186-95. doi: 10.1016/j.ajodo.2003.11.026.
31. Cattaneo PM, Dalstra M, Melsen B. Strains in periodontal ligament and alveolar bone associated with orthodontic tooth movement analyzed by finite element. Orthod Craniofac Res. 2009;12(2):120-8. doi: 10.1111/j.1601-6343.2009.01445.x.
32. Liou EJ, Chen PH, Wang YC, Lin JC. A computed tomographic image study on the thickness of the infrazygomatic crest of the maxilla and its clinical implications for miniscrew insertion. Am J Orthod Dentofacial Orthop. 2007;131(3):352-6. doi: 10.1016/j.ajodo.2005.04.044.
33. Paetyangkul A, Türk T, Elekdağ-Türk S, Jones AS, Petocz P, Darendeliler MA. Physical properties of root cementum: part 14. The amount of root resorption after force application for 12 weeks on maxillary and mandibular premolars: a microcomputed-tomography study. Am J Orthod Dentofacial Orthop. 2009;136(4):492.e1-9; discussion 492-3. doi: 10.1016/j.ajodo.2009.03.008.