Iranian Journal of Orthodontics

Iranian Journal of Orthodontics

Comparative Evaluation of Transfer Accuracy and Surface Wear of Clear Aligner Attachments Fabricated with Different Composite Resin Viscosities: An In Vitro Study

Document Type : Original Article

Authors
1 Resident, Department of Orthodontics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, India
2 Associate professor, Department of Orthodontics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, India
Abstract
Aim
This in vitro study evaluated the transfer accuracy and surface wear of clear aligner attachments fabricated using composite resins with different viscosities and two attachment designs.
Methods
Thirty‑six extracted human teeth were assigned to six groups based on composite resin type (restorative, orthodontic, or flowable) and attachment design (conventional rectangular or optimized cylindrical). Attachments were digitally planned, transferred using 3D‑printed templates, and scanned at baseline (T0) and after mounting (T1) to assess transfer accuracy. Samples then underwent simulated toothbrushing for 30,000 cycles at 2 N force before being rescanned (T2–T3). Three‑dimensional deviations between scans were quantified using Geomagic Control X. Two-way ANOVA and Tukey HSD tests were used for statistical analysis (α=0.05).
Results
Composite viscosity and attachment design showed no significant influence on transfer accuracy (P>0.05). Surface wear differed significantly among groups (P<0.001). Restorative composite resin demonstrated the least wear (mean 0.12 mm), followed by orthodontic composite resin, while flowable composite resin exhibited the greatest wear (mean 0.31 mm). Cylindrical attachments generally showed lower wear than rectangular attachments.
Conclusion
Under the conditions of this study, composite resin viscosity did not affect attachment transfer accuracy. Surface wear following simulated toothbrushing was lower in high‑filler restorative composites and in optimized cylindrical attachment designs.
Keywords
Subjects

1. Abu Arqub S, Al-Moghrabi D, Allareddy V, Upadhyay M, Vaid N, Yadav S. Content analysis of AI-generated (ChatGPT) responses concerning orthodontic clear aligners. Angle Orthod. 2024; 94(3):263-72. doi:10.2319/071123-484.1.
2. Vaid NR. Let’s talk ALIGNers!. APOS Trends Orthod. 2016;6:177-8. doi: 10.4103/2321-1407.186428.
3. Bichu YM, Weir T, Zou B, Adel S, Vaid NR. Clear Aligner therapy concerns: Addressing discrepancies between digitally anticipated outcomes and clinical ground realities. Turk J Orthod. 2024;37(2):130-39. doi:10.4274/TurkJOrthod.2024.2024.4.
4. Bhate M, Nagesh S. Assessment of the effect of thermoforming process and simulated aging on the mechanical properties of clear aligner material. Cureus. 2024; 16(7):e64933. doi: 10.7759/cureus.64933.
5. Hennessy J, Al-Awadhi EA. Clear aligners generations and orthodontic tooth movement. J Orthod. 2016;43(1):68-76. doi: 10.1179/1465313315Y.0000000004.
6. Morton J, Derakhshan M, Kaza S, Li C. Design of the Invisalign system performance. Semin Orthod. 2017;23(1):3-11.doi: 10.1053/j.sodo.2016.10.001.
7. D'Antò V, Muraglie S, Castellano B, Candida E, Sfondrini MF, Scribante A, Grippaudo C. Influence of dental composite viscosity in attachment reproduction: An experimental in vitro study. Materials (Basel). 2019 ;12(23):4001. doi: 10.3390/ma12234001.
8. Momtaz, P. The Effect of attachment placement and location on rotational control of conical teeth using clear aligner therapy. [dissertation], Las Vegas : University of Nevada; 2016.
9. Garino F, Castroflorio T, Daher S, Ravera S, Rossini G, Cugliari G, Deregibus A. Effectiveness of composite attachments in controlling upper-molar movement with aligners. J Clin Orthod. 2016;50(6):341-7.
10. Savignano R, Valentino R, Razionale AV, Michelotti A, Barone S, D'Antò V. Biomechanical effects of different auxiliary-aligner designs for the extrusion of an upper central incisor: A finite element analysis. J Healthc Eng. 2019 ;2019:9687127. doi: 10.1155/2019/9687127.
11. Vaid NR, Sabouni W, Wilmes B, Bichu YM, Thakkar DP, Adel SM. Customized adjuncts with clear aligner therapy: "The golden circle model" explained! J World Fed Orthod. 2022;11(6):216-225. doi: 10.1016/j.ejwf.2022.10.005.
12. Mantovani E, Castroflorio E, Rossini G, Garino F, Cugliari G, Deregibus A, Castroflorio T. Scanning electron microscopy analysis of aligner fitting on anchorage attachments. J Orofac Orthop. 2019;80(2):79-87. doi: 10.1007/s00056-018-00167-1.
13. Kravitz ND, Kusnoto B, BeGole E, Obrez A, Agran B. How well does Invisalign work? A prospective clinical study evaluating the efficacy of tooth movement with Invisalign. Am J Orthod Dentofacial Orthop. 2009;135(1):27-35. doi: 10.1016/j.ajodo.2007.05.018.
14. Nucera R, Dolci C, Bellocchio AM, Costa S, Barbera S, Rustico L, Farronato M, Militi A, Portelli M. Effects of composite attachments on orthodontic clear aligners therapy: A systematic review. Materials (Basel). 2022 ;15(2):533. doi: 10.3390/ma15020533.
15. Chen W, Qian L, Qian Y, Zhang Z, Wen X. Comparative study of three composite materials in bonding attachments for clear aligners. Orthod Craniofac Res. 2021;24(4):520-527. doi: 10.1111/ocr.12465.
16. Kircelli BH, Kilinc DD, Karaman A, Sadry S, Gonul EY, Gögen H. Comparison of the bond strength of five different composites used in the production of clear aligner attachments. J Stomatol Oral Maxillofac Surg. 2023;124(6):101481. doi: 10.1016/j.jormas.2023.101481.
17. Gazzani F, Bellisario D, Quadrini F, Parrinello F, Pavoni C, Cozza P, Lione R. Comparison between different composite resins used for clear aligner attachments: an in-vitro study. Front Mater. 2022;8:789143.doi: 10.3389/fmats.2021.789143.
18. Shinkai K, Taira Y, Suzuki S, Kawashima S, Suzuki M. Effect of filler size and filler loading on wear of experimental flowable resin composites. J Appl Oral Sci. 2018 ;26:e20160652. doi: 10.1590/1678-7757-2016-0652.
19. Alkhudhairy F. Wear resistance of bulk-fill composite resin restorative materials polymerized under different curing intensities. J Contemp Dent Pract. 2017 ;18(1):39-43. doi: 10.5005/jp-journals-10024-1985.
20. Jedliński M, Mazur M, Greco M, Belfus J, Grocholewicz K, Janiszewska-Olszowska J. Attachments for the orthodontic aligner treatment-state of the art-a comprehensive systematic review. Int J Environ Res Public Health. 2023 ;20(5):4481. doi: 10.3390/ijerph20054481.
21. Adel SM, Hansa I, Vaid NR. Clear aligner therapy in contemporary orthodontics : a scoping review of scholarly literature. APOS Trends Orthod. 2024;14(1): 3-27.doi: 10.25259/APOS_215_2022.
22. Sabouni W, Muthuswamy PS, Vaid NR, Adel SM. Distalization using efficient attachment protocol in clear aligner therapy—a case report. Clin Case Rep. 2023 ;11(1):e6854. doi:10.1002/ccr3.6854.
23. Demir G. Understanding the effectiveness of attachments in clear aligner therapy: navigating design, placement, material selection and biomechanics. Aust Orthod J. 2024;40(2):63-74.doi: 10.2478/aoj-2024-0021.
24. Bellocchio AM, Portelli M, Ciraolo L, Ciancio E, Militi A, Peditto M, Barbera S, Nucera R. Evaluation of the clinical variables affecting attachment reproduction accuracy during clear aligner therapy. Materials (Basel). 2023 ;16(20):6811. doi: 10.3390/ma16206811.
25. Erbas S, Atik E. A comparative in vitro study of different composite materials in terms of aligner attachment accuracy and surface roughness using different curing irradiances. Int Orthod. 2025 Jun;23(2):100961. doi: 10.1016/j.ortho.2024.100961.
26. Valeri C, Aloisio A, Mummolo S, Quinzi V. Performance of rigid and soft transfer templates using viscous and fluid resin-based composites in the attachment bonding process of clear aligners. Int J Dent. 2022 ;2022:1637594. doi:10.1155/2022/1637594.
27. Vas NV, Varghese R. An in vitro study of the abrasive potential of various toothbrushes on the surface of aligner attachments. Cureus. 2024 ;16(3):e55911. doi:10.7759/cureus.55911.
28. Roatkanjanaporn N, Chavanavesh J, Teekavanich C. Wear volumes of flowable and sculptable resin composite attachments and their correlation with retentive force of clear aligners: a laboratory study. BMC Oral Health. 2025 ;25(1):483. doi: 10.1186/s12903-025-05852-3.
29. Akcan CA, Aksoz G, Gorucu-Coskuner H, Akarsu-Guven B, Atik E. Evaluation of wear amounts of different composite resin attachments used in clear aligner treatment over a 6-month period: a retrospective study. Angle Orthod. 2026 ;96(3):318-325. doi: 10.2319/040925-281.1.
30. Ocak I, Gorucu-Coskuner H, Aksu M. Wear resistance of orthodontic attachments: a comparative analysis of different composite resins in clear aligner therapy. Clin Oral Investig. 2025 Apr 11;29(5):242. doi: 10.1007/s00784-025-06316-2.
31. Baroudi K, Rodrigues JC. Flowable resin composites: A systematic review and clinical considerations. J Clin Diagn Res. 2015;9(6):ZE18-24. doi: 10.7860/JCDR/2015/12294.6129.