Iranian Journal of Orthodontics

Iranian Journal of Orthodontics

Comparison of Initial Stress and Displacement on Vertically Displaced Canines Using the Conventional and Self-ligating Bracket Systems: A Finite Element Study

Document Type : Original Article

Authors
1 Resident, Department of Orthodontics, Sudha Rustagi College of Dental Sciences and Research, Faridabad, Haryana, India
2 Professor, Department of Orthodontics, Sudha Rustagi College of Dental Sciences and Research, Faridabad, Haryana, India
3 Professor and Head, Department of Orthodontics, Sudha Rustagi College of Dental Sciences and Research, Faridabad, Haryana, India
4 Senior Lecturer, Department of Orthodontics, Sudha Rustagi College of Dental Sciences and Research, Faridabad, Haryana, India
10.32592/ijorth.19.2.1167
Abstract
Aim: This study aimed to assess and compare the initial stress and displacement in vertically displaced canines using finite element analysis. Both conventional and self-ligating bracket systems were evaluated at displacement heights of 2, 4, and 6 mm.
Methods: Six finite element models of maxillary dentitions with canines vertically displaced by 2, 4, and 6 mm were developed using specialized software. Continuous arch wire techniques were applied in both the conventional system with 0.022" × 0.028" slot MBT brackets (3M Unitek™) and the self-ligating system with 0.022" × 0.028" slot passive self-ligating brackets (Damon Q), both utilizing a 0.014-inch CuNiTi arch wire. The study calculated canine displacement, reactionary effects on adjacent teeth (lateral incisors and first premolars), and compressive and tensile stresses along the X, Y, and Z axes at 12 specific points.
Results: The self-ligating bracket system demonstrated greater extrusion of the canine compared to the conventional bracket system, with the most significant movement observed in the 2-mm model, followed by the 4-mm and 6-mm models. Reactionary effects on adjacent teeth included intrusion and tipping away from the canine, most pronounced in the 2-mm model. Compressive and tensile stresses were higher in the conventional bracket system and decreased with increased displacement.
Conclusion: For vertically displaced canines, using a continuous arch wire with a self-ligating bracket system is more advantageous than a conventional bracket system, as it results in greater canine movement and less stress on adjacent teeth. However, its effectiveness diminishes with increased displacement height due to resistance caused by higher contact angles and decreased wire expression.
Keywords
Subjects

1. Nelson SJ, Ash MM. Wheeler’s dental anatomy, physiology and occlusion. 10th edition. St. Louis: Saunders an imprint of Elsevier Inc. 2015; P: 11-49.
2. Dewel BF. The upper cuspid: Its development and impaction. Angle Orthod. 1949;19(2):79–90. doi: 10.1043/0003 3219(1949)0192.0.CO;2
3. Moss JP. The impacted canine. Dental Practioner. 1972;22:241–48.
4. Moyers RE, van der Linden FP, Riolo ML, McNamara Jr. Standards of human occlusal development. 1st edition. Ann Arbor: Center for human growth and development. 1976. P: 150 211.
5. Bishara SE. Clinical management of impacted maxillary canines. Semin Orthod. 1998;4(2):87-98. doi: 10.1016/s1073-8746(98)80006-6.
6. Jain S, Debbarma S. Patterns and prevalence of canine anomalies in orthodontic patients. Med Pharm Rep. doi: 10.15386/cjmed-907. 2019;92(1):72-8.
7. Frank CA, Nikolai RJ. A comparative study of frictional resistances between bracket and arch wire. Am J Orthod. 1980;78(6):593-609. doi: 10.1016/0002-9416(80)90199-2.
8. Pizzoni L, Ravnholt G, Melsen B. Frictional forces related to self-ligating brackets. Eur J Orthod. 1998;20(3):283-91. doi: 10.1093/ejo/20.3.283.
9. Hain M, Dhopatkar A, Rock P. The effect of ligation method on friction in sliding mechanics. Am J Orthod Dentofacial Orthop. 2003;123(4):416-22. doi: 10.1067/mod.2003.14.
10. Harradine N. Self-ligating brackets: theory, Practice, and Evidence. In: Graber LW, Vanarsdall RL, Vig K, Huang GJ, editors. Orthodontics: current principles and techniques, 6th edition. St. Louis: Elsevier; 2017. P:730-760.
11. Baccetti T, Franchi L, Camporesi M, Defraia E, Barbato E. Forces produced by different nonconventional bracket or ligature systems during alignment of apically displaced teeth. Angle Orthod. 2009;79(3):533-9. doi: 10.2319/050508 249.1.
12. Baccetti T, Franchi L, Camporesi M, Defraia E. Orthodontic forces released by low-friction versus conventional systems during alignment of apically or buccally malposed teeth. Eur J Orthod. 2011;33(1):50-4. doi: 10.1093/ejo/cjq043.
13. Tominaga JY, Ozaki H, Chiang PC, Sumi M, Tanaka M, Koga Y et al. Effect of bracket slot and archwire dimensions on anterior tooth movement during space closure in sliding mechanics: a 3 dimensional finite element study. Am J Orthod Dentofacial Orthop. 2014;146(2):166-74. doi: 10.1016/j.ajodo.2014.04.016.
14. Tanne K, Sakuda M, Burstone CJ. Three dimensional finite element analysis for stress in the periodontal tissue by orthodontic forces. Am J Orthod Dentofacial Orthop. 1987;92(6):499-505. doi: 10.1016/0889-5406(87)90232-0.
15. McGuinness NJ, Wilson AN, Jones ML, Middleton J. A stress analysis of the periodontal ligament under various orthodontic loadings. Eur J Orthod. 1991;13(3):231-42. doi: 10.1093/ejo/13.3.231.
16. Wilson AN, Middleton J, Jones ML, McGuinness NJ. The finite element analysis of stress in the periodontal ligament when subject to vertical orthodontic forces. Br J Orthod. 1994;21(2):161-7. doi: 10.1179/bjo.21.2.161.
17. Kim SJ, Kwon YH, Hwang CJ. Biomechanical characteristics of self-ligating brackets in a vertically displaced canine model: a finite element analysis. Orthod Craniofac Res. 2016;19(2):102 13. doi: 10.1111/ocr.12119.
18. Chaushu S, Bongart M, Aksoy A, Ben-Bassat Y, Becker A. Buccal ectopia of maxillary canines with no crowding. Am J Orthod Dentofacial Orthop. 2009;136(2):218-23. doi: 10.1016/j.ajodo.2007.10.047.
19. Sachan A, Chaturvedi TP. Orthodontic management of buccally erupted ectopic canine with two case reports. Contemp Clin Dent. 2012;3(1):123-28. doi: 10.4103/0976-237X.94563.
20. Burstone CJ, Choy K. The biomechanical foundation of clinical orthodontics. Batavia: Quintessence Publishing Co. 2015; P: 5-168.
21. Nanda RS, Tosun YS. Biomechanics in orthodontics, Principles and Practice. 1st edition. Hanover Park : Quintessence Publishing Co. 2010; P:38-39.
22. Kusy RP, Whitley JQ. Friction between different wire-bracket configurations and materials. Semin Orthod. 1997;3(3):166-77. doi: 10.1016/s10738746(97)80067-9.
23. Kusy RP, Whitley JQ. Influence of archwire and bracket dimensions on sliding mechanics: derivations and determinations of the critical contact angles for binding. Eur J Orthod 1999;21(2):199-208. doi: 10.1093/ejo/21.2.199.
24. Franchi L, Baccetti T. Forces released during alignment with a preadjusted appliance with different types of elastomeric ligatures. Am J Orthod Dentofac Orthop. 2006;129(5):687-90. doi: 10.1016/j.ajodo.2005.11.028.
25. Fok J, Toogood RW, Badawi H, Carey JP, Major PW. Analysis of maxillary arch force/couple systems for a simulated high canine malocclusion: Part 1. Passive ligation. Angle Orthod. 2011;81(6):953-9. doi: 10.2319/012011-40.1.
26. Ali MI, Al Sheakli II, Al Zaidee SR. Biomechanical Analysis of Orthodontic Correction of Buccally Malposed Canine: A Finite Element Analysis. J Res Med Dent Sci, 2021, 9 (2): 43-51.
27. McGuinness NJ, Wilson AN, Jones ML, Middleton J. A stress analysis of the periodontal ligament under various orthodontic loadings. Eur J Orthod. 1991;13(3):231-42. doi: 10.1093/ejo/13.3.231.