Orthodontics
Nirali Mehulbhai Shah; Khyati Viral Patel; Ajay Kubavat; Manish Desai; Harshit Arvindbhai Patel; Nikunj Harikrushn Prajapati
Abstract
Aim: The aim of the in vitro study was to examine the enamel surface after the application of four different methods for adhesive removal following the bracket debonding procedure, as well as to compare their effects on enamel surface.Methods: Premolars (n=60) were randomly assigned to four groups. After ...
Read More
Aim: The aim of the in vitro study was to examine the enamel surface after the application of four different methods for adhesive removal following the bracket debonding procedure, as well as to compare their effects on enamel surface.Methods: Premolars (n=60) were randomly assigned to four groups. After initial debonding and recording the shear bond strength (SBS), adhesive remnant index (ARI) scores were assessed. The removal method for each of the four groups was the use of 1) a round bur, 2) rubber wheel bur, 3)12 fluted tungsten carbide bur, and 4) scaler. After that, teeth in all four groups were kept in artificial saliva for one month. After rebonding with a new bracket, again the SBS and ARI scores were measured. Two representative samples from each group were examined under a scanning electron microscope. ……. P-value <0.05 was considered as significant. ANOVA test was used to assess the SBS association within the group. Paired T test was used to assess the SBS between the group. fisher’s exact test was performed to compare ARI index before and after.Results: There was significant decrease in secondary SBS value in group 1 but significant increase in secondary SBS value in group 3, and a slight decrease in SBS value in group 4. In SEM images, there were composite remnants in all the four groups with fewer remnants in group 2. Enamel surface damage was observed in the SEM image of group 3. ARI scores showed no significant difference.Conclusion: Adhesive remnant removal efficiency of the round bur and scaler are less. Rubber wheel bur is a good choice of instrument for removal of adhesive remnants from tooth surface as it does not affect the bond strength. Tungsten carbide bur shows good results, as secondary bonding SBS value increased. Significant difference between ARI scores did not exist, indicating a higher number of mixed type failure in all groups.
Vasim Pinchani; Ajit J Kalia; Kannan Sharif; Salil Nene; Nasim Mirdehghan; Khadija M Dalvi
Abstract
Background: Friction plays a major role during tooth movement as it takes up to 60% of the applied force, hence reducing the force available for tooth movement. Coating the surface of orthodontic wires by various techniques is being developed to improve their mechanical and biological properties.Objectives: ...
Read More
Background: Friction plays a major role during tooth movement as it takes up to 60% of the applied force, hence reducing the force available for tooth movement. Coating the surface of orthodontic wires by various techniques is being developed to improve their mechanical and biological properties.Objectives: To evaluate the characteristics of nano particle coated and uncoated stainless steel, nickel-titanium, and beta-titanium wires for (1) coating stability, (2) surface characteristics and (3) biocompatibility after 21 days of exposure to artificial saliva.Methods: Six types of wires were tested for coating stability, surface characteristics before and after exposure to artificial saliva using scanning electron microscope and the artificial saliva was tested for leaching of ions by inductively coupled plasma optical emission spectrometer. Results: Coating thickness was reduced in each group after exposure to artificial saliva which was statistically significant. Significant changes in surface morphology such as delamination and irregularity of the coating was noted. Coated NiTi wires showed lesser leaching of ions when compared with uncoated NiTi wires but the difference was not statistically significant.Conclusions: Coating delamination and irregularities were seen in many areas. The highest concentration of ions leached among all the groups were of iron, followed by silica.