Roya Naseh; Nima Rahnamoon; Maryam Afshari
Abstract
Background: Assure Universal Bonding Resin is capable of providing a strong bond between orthodontic attachments and amalgam surfaces.
Objectives: This study sought to assess the shear bond strength of orthodontic attachments to amalgam surfaces using Assure Universal Bonding Resin after different surface ...
Read More
Background: Assure Universal Bonding Resin is capable of providing a strong bond between orthodontic attachments and amalgam surfaces.
Objectives: This study sought to assess the shear bond strength of orthodontic attachments to amalgam surfaces using Assure Universal Bonding Resin after different surface treatments.
Methods: This in-vitro experimental study was conducted on 120 amalgam samples in eight groups of surface roughening with diamond bur, sandblasting with aluminum oxide particles, Er, Cr: YSGG laser irradiation and polishing-only. Molar buccal tubes were bonded to amalgam surfaces using Assure primer and Transbond Plus light-cure composite. Half the samples were immediately subjected to shear bond strength testing while the remaining half were incubated at 37°C for one week, thermocycled (1000 cycles) and were then subjected to shear bond strength test. One-way ANOVA was applied to compare the bond strength of the groups and Tukey’s test was used for pairwise comparisons. The adhesive remnant index (ARI; 4 point-scale) was also determined in the groups and the results were analyzed using the Kruskal-Wallis test. Results: Significant differences were noted in shear bond strength of attachments following the application of Assure among different surface treatment modalities (P < 0.001); the highest bond strength was noted in sandblasted group followed by laser, bur and polishing, respectively. Aging had no significant effect on bond strength.
Conclusions: Sandblasting and irradiation of Er, Cr: YSGG laser provided sufficiently high bond strength between amalgam and attachments following the application of Assure. Diamond bur and polishing did not provide adequately high bond strength.
Mashallah Khanehmasjedi; Mohammad Ali Naseri; Samaneh Khanehmasjedi
Abstract
Objectives: The present study was carried out to compare the shear bond strength of metallic brackets bonded with single Bond and Assure bonding agents under dry and saliva contamination conditions. Materials and Methods: A total 60 sound premolar teeth were selected for the purpose of this in vitro ...
Read More
Objectives: The present study was carried out to compare the shear bond strength of metallic brackets bonded with single Bond and Assure bonding agents under dry and saliva contamination conditions. Materials and Methods: A total 60 sound premolar teeth were selected for the purpose of this in vitro study and stainless steel brackets were bonded on enamel surfaces with single bond and assure bonding agents under a dry condition or with salivary contamination. The shear bond strength values of the brackets were measured in a universal testing machine. The adhesive remnant index (ARI) scores were determined after debonding of the brackets under a stereomicroscope. One-way ANOVA was used to analyze bond strength. Two-by-two comparisons were made with post hoc Tukey tests (P < 0.001). The frequencies of ARI scores were analyzed with Kruskal-Wallis test. Results: The bond strength values of brackets to tooth structure were 9.29 ± 8.56 and 21.25 ± 8.93 MPa with the use of Assure resin bonding agent under saliva contamination and dry conditions, respectively. These values were 10.13 ± 6.69 and 14.09 ± 6.6 MPa, respectively, under the same conditions with the use of single bond adhesive. Contamination with saliva resulted in a significant decrease in the bond strength of brackets to tooth structure with the application of Assure adhesive resin (P < 0.001). There were no significant differences in the ARI scores between the different study groups.
Conclusions: Application of single bond and assure bonding agents resulted in adequate bond strength of brackets to tooth structures. Contamination with saliva significantly decreased the bond strength of Assure bonding agent compared to dry conditions.